高级检索

    燃煤机组脱硫双塔及相关系统颗粒物脱除特征

    Characteristics of particulate matter removal in two-stage WFGD and related systems of a coal-fired power plant

    • 摘要: 为了探究装配双级脱硫塔的燃煤机组对颗粒物脱除特性的问题,通过低压撞击器颗粒物取样系统对西安某300 MW机组双级串联湿法脱硫塔及相关污染物控制设备进出口颗粒物现场采样,并搭建滤膜取样系统,收集脱硫塔进出口处的颗粒物进行水溶性离子分析。结果表明:双级脱硫塔对PM10的总脱除效率为60.3%,PM1的质量浓度未出现逆增长现象,脱硫出口处PM10水溶性离子中SO42-、Cl-、Mg2+含量增加;选择性催化还原装置会使得PM1的质量浓度增加24.7%;静电除尘器对PM2.5-10、PM1-2.5、PM1的脱除效率分别为98.6%、98.3%、95.7%;湿式静电除尘器对各级颗粒物脱除效率均达到60%以上。70%负荷下,该机组排放的PM10质量浓度为2.89 mg·m-3,排放因子为0.049 kg·t-1

       

      Abstract: In order to explore the characteristics of particulate matter (PM) removal during two-stage flue gas desulfurization, a Dekati low pressure impactor was used to determine PM concentration at the inlet and outlet of each air pollutant control device of a 300 MW power plant in Xi'an. A sampling system was set up at the inlet and outlet of the desulfurization system for collecting particles to analyze water-soluble ions. The results show that the PM10 removal efficiency in the desulfurization system is 60.3%, and the mass concentration of PM1 does not show the reverse growth phenomenon. The water-soluble ion contents of SO42-, Cl- and Mg2+ in PM10 increased at the outlet of the desulfurization system. The mass concentrations of PM1 increased by 24.7% in the selective catalytic reduction system. The removal efficiencies of electrostatic precipitator for PM2.5-10, PM1-2.5 and PM1 were 98.6%, 98.3% and 95.7%, respectively. The removal efficiency of wet electrostatic precipitator was over 60%. The mass concentration of PM emission was 2.89 mg·m-3 and the emission factor was 0.049 kg·t-1 under 70% load.

       

    /

    返回文章
    返回